Translate

Monday, August 17, 2009

new version of motor analyzer released

This is the latest version, 1.6, just released. It does VAWT and HAWT now and will save 3 motor configurations. If you have already purchased in the past, I will upgrade you for free. Just send me an email. There is a part that I'll change on the next release. It says, "Power from blades after friction losses" and should now read, "power from blades after all losses".

I'll make a video of the new program in action and post it on youtube and here.

have a good monday,
Richard

Friday, August 14, 2009

Scalable First Flush System for Rainwater Collection

gutter debris deflection




first flush systemHere is a simple idea for a "first flush" system for rainwater collection. It is made of pvc pipe and the first flush section is made of 4 inch pipe. For every 18.5 inches used, it will hold 1 gallon. It is scalable by adding more pipes to the left side. I could use 2 pipes at 46 inches each and get 5 gallons of first flush capability, for example. The pipes have a bottom cap and a small hole drilled in them. This way, when the rain starts falling, the first 5 gallons would go into these pipes and fill up faster than the small holes at the bottom will drain. After the pipes fill up, the water (now clean) overflows into the storage tank. This process rinses away bird droppings, leaves, dust, bugs, etc. If you have a larger roof, you may want more first flush, such as 10 gallons or more. It also helps to have a way to stop the leaves and big stuff from even getting this far. Some people use screened gutters, or a screened redirector right before it goes into the first flush section.

You guys have a good weekend.

Richard


   
Amazon.com
$31.65

Amazon.com
$32.35





Wednesday, August 12, 2009

update solar oven


Got some flat black barbecue paint and painted the solar oven. I will let it dry tonight and then tomorrow put it in the sun to make sure any toxins can gas out. It is high temp paint but I'd like to be safe. Then we can start using it.

Remember, this one doesn't have insulation. When the temp outside is a little cooler, I'll raise efficiency by using the hot box cooker technique. I'll take a bigger box and place a thick blanket over it and push this cooker down into that so that all sides except the top are covered and well insulated.

Most people would build in the insulation but there are issues with that. Whenever the food steams it could get the insulation wet and mess it up. The hot box way means I can take out the insulation super easy after I'm done and let it dry if it gets wet.

Richard

Rooftop Savonious Discussion

I'd like to talk a little about a vertical axis wind turbine positioned on its side. Yeah, I know, it becomes a HAWT when you do that. The main problem is that, in that position, it doesn't spin from all wind. But there are some advantages. Firstly, it is low profile and neighbors are less likely to complain. Secondly, it is technically easier to mount this way. Standing straight up means the mount point has to be way stronger due to massive torque effects. And thirdly, you can link several wind turbines in a row to share shaft power to one powerful generator.

There is also an advantage to putting a VAWT on the rooftop. When the wind comes, it is compressed upward and effectively gives the savonious more surface area of wind collection. If the wind is traveling perpindicular to the axis then you will get your maximum power potential. In the below example, there is a VAWT 8 feet long and 4 feet wide and it s laying down on its side at the rooftop. In this example the roof rises 8 feet. That means that whatever power the wind turbine would generate in a given wind is multiplied by 3. Of course, a different roof and sized wind turbine would generate different results. So, if it ran at 15 % efficiency normally, then on the rooftop it could be up to 45% efficient. Also note that wind at the peak of the house is stronger than wind at the ground level.

In the below picture you will see wind angles at 45 degrees from perpindicular to the axis. At 45 degrees, the wind turbine should appear to have half the surface area. So, half of 45% would be 22.5% efficiency, still good. At 60 degrees off perpendicular, the silhouette would become one third of full and, in spite of the roof, would make the overall efficiency become 15%. In other words, you can get normal power even at extreme angles. And at perpindicular angles, get 3 times the normal power output.

Some roofs have sections that are perpindicular to each other. Another VAWT could be mounted there as well. That way you generate power no matter what direction the wind comes from. And even if you only have one, whenever the wind direction changes back to a better angle, the power increase more than makes up for the times when no power was generated. Just make sure that your predominant wind is the right direction, otherwise this just wouldn't work for you.

Richard

Tuesday, August 11, 2009

DC Motor Analyzer Finished

Well, it looks like I've finished the updates on my DC motor analyzer software. I still have to do some more testing before I make it available but here are some screenshots. The yellow highlighted sections are new parts to the program. They are only highlighted here for you to see, the program normally doesn't show that. The first picture below is in the HAWT mode, or horizontal axis wind turbine. The second picture is in VAWT mode. So, you can do savonious or other vertical axis wind turbines.



Something to be aware of if you go to the VAWT calculator web page on my website, is that those computations also account for about a 55% efficiency dc motor. So, if you take a savonious and the blades are 15% efficient and the motor is 55%, then on the new motor analyzer software you would put in 8% efficiency. On the website, this was done in the background. But the new program gives you more control.

For instance, if you have blades that are 30% efficient for a HAWT and your DC motor is 60% efficient, then you can put 18% in the efficiency field and get a nice "real world" expectation. Especially when you put in the cable length and gauge.

I should have my testing done by this weekend at the latest and the new analyzer should be available for purchase.

Richard